AC not turning on: the five-minute checklist

5 minute readWritten by the Kessler technicians

Short answer

If your AC will not turn on, check in this order: thermostat batteries and mode, the breaker, the condensate float switch, the filter, and the outdoor disconnect. Three of these are free fixes. The rest need a technician.

AC not turning on: the five-minute checklist

Work through these in order

  • Thermostat batteries. A dead battery in a battery-powered thermostat looks exactly like a dead air conditioner. Replace them first, every time.
  • Thermostat mode and setpoint. COOL selected, and set at least three degrees below the current room reading. Some systems will not call for cooling on a smaller gap.
  • The breaker panel. Look for a breaker sitting between ON and OFF. Push it fully OFF, then firmly back ON. If it trips again immediately, stop and call. A repeatedly tripping breaker is a fault, not an inconvenience.
  • The outdoor disconnect. There is a small box near the outdoor unit with a pull-out handle. It can be knocked loose by landscaping work. Make sure it is seated fully.
  • The condensate float switch. On attic and closet systems, a clogged drain fills a pan and trips a switch that shuts cooling off on purpose, to stop water coming through your ceiling. If the pan has water in it, this is your answer.
  • The filter. A filter so clogged it froze the coil will shut the system down. If you see ice, turn the system off, set the fan to ON to thaw it, and replace the filter.
  • The indoor unit switch. Many air handlers have a light-switch style shutoff nearby that gets flipped by mistake, often by someone looking for the attic light.
  • Anything else. If all eight check out, the fault is electrical or mechanical, and it needs someone with a meter.

What each outcome usually means

Breaker trips again immediatelyShort or failing compressor. Stop and call.
Humming outside, fan not spinningAlmost always the capacitor. $180 to $320.
Water in the drain panClogged condensate line. $150 to $290.
Nothing at all, no displayThermostat power or a control transformer.
Runs but trips after a few minutesOverheating, often airflow or a failing motor.

When to skip the checklist entirely

If you smell burning, if a breaker trips more than once, or if it is above 95 outside with an infant, an elderly resident, or someone with a medical condition in the house, do not work through a list. Call, and say who is in the house.

There is no charge for asking, and no overtime charge for the hour you happen to be asking at.

Your AC quit. Cold air by tonight.

Two ways to start. Pick whichever suits the state you are in right now.

It's broken now(704) 555-0147A person answers, 24 hours a day. Same price at 2am.

We call back within 30 minutes during business hours. Licensed H3-XXXXX.

Call now